Backup and Redundancy > Detailed Directions > Engaging a Failover of an External Device > Changing the Signal Path from the Backup to the Main using the Single Bus Application
 
Changing the Signal Path from the Backup to the Main using the Single Bus Application
After completion of an Engage Failover, the following procedure explains how to return the signal path from the backup to the main.
 

NOTE: The following procedure includes steps that use the iControl Router Manager. For details about iControl Router Manager configuration, see the iControl Router Manager Quick Start Guide.

 
REQUIREMENT:  
Before beginning this procedure, make sure you have opened iControl for the Application Server running the router service (click HERE).
1. On the iControl—Startup page, click iC Router Control.
System Response: The Router Manager page appears.

[ Graphic ]  

2. In the row corresponding to the router requiring configuration, click Single bus.
System Response: A Single Bus window appears.

[ Graphic ]  

3. Click the arrow button in the Destination area.

[ Graphic ]  

System Response: The Destination/Group window appears.
4. Select an output/destination, and then click OK.
System Response: The Single Bus window re- appears.
5. Select a source, and then close the window.
 

NOTE: Crosspoint changes are live.