Getting Started with iControl > Key Concepts > Lookup Services > Alarm Publication Lookup Table
 
Alarm Publication Lookup Table
Services, such as Densité Manager, automatically publish their alarms on GSMs within the same subnet as the Application Server hosting the service. However, if you would like alarms to be visible to a GSM outside the local subnet, you must specify the IP address of the external Application Server (the server hosting the lookup service where the target GSM is registered) in the Alarm publication table of the iControl Lookup locations page.

[ Graphic ] 

 

IMPORTANT: System behavior  

If the Alarm publication table of Application Servers is empty, the Densité Manager on the local Application Server publishes its alarms exclusively on the local GSM and active GSMs on Application Servers within the subnet.

If the Alarm publication table is populated with the IP address of a non-local Application Server, and you would like the local GSM to see alarms originating from the local Densité Manager, you must also include the IP address of the local Application Server.

 
 

See also:  

For more information, see: 

"Examples: Alarm Publication Lookup Scenarios".

"About the Alarm Publication Lookup Table".