Monitoring System Components
The System page provides an overview. The following example has a Primary Chassis with three Expansion Chassis
Component | Count | Description |
---|---|---|
Boot Drives | 4 | Primary Chassis = 4 (quantity = 2 M.2 SSD per
controller) Expansion Chassis = n/a |
Fans | 28 | Primary Chassis = 16 (8 per
controller) Expansion Chassis = 12 (4 per chassis) |
NVD Drives | 2 | Primary Chassis = 2 (quantity = 1 M.2 SSD per
controller) Expansion Chassis = n/a |
Power Supplies | 8 | Primary Chassis = 2 (1 per
controller) Expansion Chassis = 6 (2 per chassis) |
Storage Drives | 48 | Primary Chassis = 12 (12 per
chassis) Expansion Chassis = 36 (12 per chassis) |
SW RAID Devices | 14 | User storage utilizes RAID-6 so one RAID set = 6
drives Primary Chassis = 2 Expansion Chassis = 6 (2 per chassis) Boot Drive RAID = 4 (RAID-1) NVD Drive RAID = 2 (RAID-1) |