Front View

AMS Express with front bezel. The front bezel should be installed after rack mounting the server and remain installed for proper cooling of the unit.

A fully loaded system is shown below with the front bezel removed. The unit contains 12 drive bays that are numbered as shown.

The Control Panels on either side of the system contain LEDs and Buttons correspond to their respective controllers and each drive bay has LEDs described below.

Item Component
1 Left Front Control Panel (Controller A)
2 Right Front Control Panel (Controller B)

Control Panel LEDs and Buttons (both control panels)

Item LED/Button* Indication/Function
1 Controller Power Status (LED/button)
  • Blue: Power on
  • Off: Power off
2 Controller ID (LED/button)
  • Blue: Controller ID enabled
  • Off: ID not lit
3 Controller Status (LED)
  • Red: Controller degraded
  • Off: Controller healthy
4 LAN Port 1 Activity
  • Yellow: LAN1 (10 GbE) network activity
  • Off: LAN1 link is down
5 LAN Port 2 Activity
  • Yellow: LAN2 (10 GbE) network activity
  • Off: LAN2 link is down
6 NVD Save/Restore Activity Blinking: NVD is saving or restoring data
7 NVD PCIe Up/Ready On = NVD is healthy and connected to the PCIe interfaces
*LED/button displayed is specific to each controller's panel: Controller A - left control panel; Controller B - right control panel

LEDs for each drive

Item LED location LED State
1 Top Drive LED
  • Off: System off or drive not fully-seated
  • Solid Blue: Online/Healthy status
  • Blinking Blue: Drive access detected
2 Bottom Drive LED
  • Off: Healthy; no drive failure detected
  • Solid Red: Drive error

Copyright © 2021 - 2022 GVBB Holdings SARL and Grass Valley USA, LLC. All rights reserved. Specifications are subject to change without notice. AMS Express 1.5 gvtp_20220429_09:58:17