STR-67687 Description: GV I/O channel fails to record after switching the video format.
Workaround: When changing a video feed on the GV I/O appliance, the signal feed on the SDI input of the AJA card must be set first. Then in GV STRATUS Control Panel, change the Channel Format in General | Channels | GV I/O settings to match the format of the new video feed.
STR-67999 Description: GV I/O channel fails to cue and playout a clip that has both 16-bit and 24-bit audio tracks.
Workaround: Make sure all audio tracks in the clip are of the same type.
STR-68445 Description: GV I/O channel's Record and Playout-specific options do not update in the Channel Panel tool after changing them in the GV STRATUS Control Panel.
Workaround: The GV STRATUS desktop application needs to be restarted after changing a GV I/O channel from Playout to Record or from Record to Playout in order to see updated configuration options in the Channel Panel tool.
STR-69574 Description: When setting mark in/out for a 720p XDCAM Long GOP asset using a GV I/O channel, the marks will be forced to the nearest even video frame.
Workaround: None.
STR-69723 Description: Changing a GV I/O channel input to SMPTE 2110 from either SDI, SMPTE 2022-6, or Web Stream, after previously saving a different SMPTE 2110 channel allows saving the channel configuration without uploading a new SDP file.
Workaround: Set the SDP file for the particular channel before saving your settings. If not, the channel will be configured with an incorrect SDP file from another SMPTE 2110 channel.
STR-71412 Description: For GV I/O channels configured for SMPTE 2110 Playout, if the Audio Format setting is configured for "L16/48000 Hz", loading a clip to the channel for playout will fail.
Workaround: For GV I/O channels configured for SMPTE 2110 Playout, set the Audio Format setting to "L24/48000 Hz".
MOC-1122 Description: Time Of Day recordings starts a few frames early on SDI inputs.
Workaround: Restart the Appservice.
MOC-1140 Description: Playback latency are not constant across SDI outputs.
Workaround: Latency between channels can be improved by restarting the Appservice.