EDIUS/XRE Setup for K2 Central
- Install/upgrade EDIUS and XRE/Render Engine software as directed by standard instructions in GV STRATUS customer documentation. Make sure you follow the proper sequence for installation and running applications.
- On the K2Central server, share the V: drive.
- Add an EDIUS project folder at the root of the V: drive, as directed by standard instructions in GV STRATUS customer documentation.
- Mount the V: drive to your XRE/Render Engine server and any high resolution STRATUS/EDIUS clients.
-
In GV STRATUS Control Panel, click Applications | EDIUS | Default Project Settings and set
Default project location to
the UNC path of the above EDIUS folder, as follows:
- For K2 Central, use a path to the EDIUS folder
on the K2 Central server, such as the following:
\\[K2CentralServerName]\V\[EdiusFolderName]
Note: If there are multiple K2s on the GV STRATUS system besides the K2Central, then the EDIUS project folder may be located on a different K2. - For K2 Central, use a path to the EDIUS folder
on the K2 Central server, such as the following:
- In the EDIUS XRE Server tab, configure the XRE Server setting to the desired GV Render Engine server.
- Follow the instructions in the this Topic Library to complete EDIUS and XRE/Render Engine setup for CIFS mount.
- In the Core | Engines settings, verify that each GV Render Engine is displayed, desired streams configured, and the engine status is running.
-
On each GV Render Engine server, do the following:
- Manually map the K2 Central’s V: drive (and any other desired K2s) using the FTP IP addresses. For example, if the FTP IP address of K2 Central is 10.148.1.150, then map the K2 Central V: drive as \\10.148.1.150\V, and choose the Reconnect at logon option.
- On the XRE Admin Console | XREController setting window, save Project folder configuration to the same directory as the EDIUS project location.
-
In XRE Admin Console | GVRenderEngine:
- Set the Node name to the local server name.
- Click the Setting… button and set the primary GV Render Engine name, address, and the port number as 1223.
- Check the server name and click the Connected test button to verify that it’s connected to the primary GV Render Engine.
-
In XRE Admin Console | Plug-in:
- Select the K2 (SAN) | Server.
- Select the Configure automatically box and verify that all desired K2s, including the K2Central, are displayed.
- Deselect the Configure automatically box.
- Modify each K2 Server manually, by changing the password or drives, if desired.
- Exit the XRE configuration utility.
-
Restart the entire GV STRATUS system in the
following order:
- B1 proxy server (if applicable)
- K2 Central servers, Stand-alones, primary FSMs
- Secondary FSMs (if applicable)
- All K2 Summits, iSCSI clients, GVREs, PCs
- Core/Workflow/DME servers
- Open Embedded Security Managers on the K2 Central and K2 Summit clients, and put them in Enabled mode.