Installing software on a Proxy server
Only systems with proxy on the K2 SAN require this process. Use SiteConfig to install software on the GV STRATUS server with role of Proxy Server that is attached to the K2 SAN.
- Verify the SiteConfig roles currently assigned to the server. If the roles are not correct for your system design, add or remove roles accordingly. Roles are as follows:
- Add the server to a deployment group, such as the GV STRATUS deployment group.
-
Add the following
files to the deployment group:
- GrassValley_CoreServer_x.x.x.cab, which contains the following cab files that apply to this device:
- GrassValley_STRATUSClient_x.x.x.cab.
- For K2 9.8.x systems; use GrassValley_K2system_x.x.x.cab, which contains the following cab files that apply to this device:
- For K2 10.x systems; use GrassValley_K2Plus_x.x.x.cab, which contains the following cab files that apply to this device:
-
Do the SiteConfig
Check
Software operation on the server.
Note: If an "Unable to copy ... to target" error appears for a device that has the Grass Valley Embedded Security solution, apply the Embedded Security solution one-time initial deployment process to the device. After the one-time process is complete the error does not appear and it is no longer necessary to put Embedded Security in Update mode.
- Verify that deployment tasks are set to Install for the files listed above. If a WFRegMon install task appears, install it as well. It is required to support Grass Valley software installers. There is no uninstall task.
- Deploy software to the server.
- Restart as prompted.