Upgrade GV STRATUS system with the Key Upgrade Utility
- Log on to the GV STRATUS Core server as an Administrator.
-
Locate the following file:
C:\Program Files\Grass Valley\STRATUS Core Services\KeyUpgradeUtility.exe
This file is copied to the GV STRATUS Core server along with the software upgrade.
-
Run the KeyUpgradeUtility.exe to
upgrade the encryption keys on your GV STRATUS Core server.
Note any yellow messages in the output and take the requested action; these will occur at the end of the utility execution.
The process is successful when the Complete! message displays at the end of the output.
-
In the Proxy Config | Proxy Settings tab in GV STRATUS Control Panel, re-check the
Enable Proxy Creation setting and click
Save.
Verify all pop-ups succeed before continuing.
- Reboot the GV STRATUS Core server.
- Re-enable any rules that were disabled earlier.
-
Procure and run the EngineConfig_6_8.cmd file where any of
the following engines are installed and running:
- DataMover Engine
- Transcode Engine
- Workflow Engine
- Rules Engine
- Social Media Engine
- External Media Engine