Installing the Sealevel SeaI/O-410E GPIO Controller
GV STRATUS Rundown has been qualified to work via ethernet connection with the following device:
- Sealevel SeaI/O-410E GPIO Controller
-
Download and install the Sealevel GPIO SeaI/O-410E device software from the
Sealevel download
page.
The Software Installation window appears and the driver software installs automatically.
- Go to Start | Programs | Sealevel Systems - SeaMAX and launch the MaxSSD application.
-
Click the COM Port drop-down list and select
Ethernet.
The configured IP address of the device appears on the right of the Host PC Configuration tab.
-
Select the IP address.
The selected IP address automatically populates after a connection verification process.
The Module Configuration tab appears.
- Go to the Module Configuration tab and select the configured Slave ID of the device.
- Click on the Get Module Settings button to get the device settings.
- Go to the Digital IO tab and set the Bank Selection setting to 3-4 from the drop-down list.
- Under Digital Outputs setting, set Bit 1, Bit 2, and Bit 5 to ON.
- Click the Close MaxSSD button to close the application.
- Relaunch the GV STRATUS Rundown application.
- Go to Tools | Options and select the GPIO Configuration tab.
- Select Ethernet for the Device Type, set the IP Address, Slave ID, and select the Enable General Purpose Output check-box.