GV STRATUS proxy encoding test

Do this for all systems with Render Engines. Whether you received your system pre-configured from Grass Valley or you configured your system on site, you should test the proxy encoding from one GV STRATUS client PC before proceeding.
  1. In the GV STRATUS application, identify a high-resolution asset and do the following:
    1. In the Navigator, select the high-resolution asset on the K2 Summit system. The asset appears in the Asset List.
    2. Display the Has Proxy column in the Asset List.
    3. Verify that the asset has a proxy association.
    4. Make sure the asset has not recently been used by any GV STRATUS tool or panel.

      An asset can retain an association with the tool or panel that recently used it and prevent proxy from being regenerated.

  2. In the Asset List, right-click the high-resolution asset and select Regenerate Proxy.
  3. Verify the following behavior:
    1. In the Associations tab of the Inspector, the proxy association is momentarily not visible. This occurs as the GV STRATUS system deletes the proxy asset.
    2. In the Associations tab of the Inspector, the proxy association shows as recording. This occurs due to the GV Render Engine is in the process of regenerating the proxy asset.
    3. In the Associations tab of the Inspector, the proxy association is visible again. This occurs as a result of the GV Render Engine has finished regenerating the proxy asset.

Copyright © 2020 Grass Valley Canada. All rights reserved. Specifications subject to change without notice. GV STRATUS 6.10 gvtp_20200811_04:57:17