Send Destination Add/Modify settings

These settings are optional on GV STRATUS systems.

To locate these settings, click General | Locations Config | K2 - Send Destinations | Add or Modify

Setting or button Description
Send Name The name of the destination, as it appears in the Send Destinations list in the GV STRATUS application. This can be any name, as appropriate for your workflow.
K2 The destination system to which the asset is sent.

If the destination is a K2 Summit/SAN system, it must be configured in K2 Storage , K2 SAN Storage, K2 Standalone Storage, or Remote K2 Storage settings.

If the destination is a redundant K2 SAN system, the same send locations must to be configured for both primary and backup systems.

If the destination is specified to use a separate FTP network (typically designated with the _he0 suffix), that FTP network must be accessible when configuring these settings.

If the destination is not a K2 Summit/SAN system, Non-Summit device must be selected.

Conform on Send Triggers the Render Engine software component to render a complex asset as a simple clip. It is recommended that the Send Name indicate that the destination is configured for conform.
Output Format Conform on Send must be selected to populate this setting. This is the output format to which sent assets are conformed. Output formats on the list are configured in Format settings. The only formats available are those compatible with the Reference Standard currently configured in Format settings.
Restripe timecode When selected, the start timecode of the conformed clip is set according to the EDIUS Start Timecode setting in GV STRATUS Control Panel. This setting is automatically selected when the Conform on Send box is checked.

If not selected, the start timecode of the conformed clip is preserved according to original timecode.

Note: The Restripe timecode option is only supported for same-format conforms (e.g.: 720p to 720p).

For mixed-format conforms (e.g.: combination of 720p and 1080i), the resultant clip always consists of restriped timecode according to EDIUS Start Timecode setting regardless of selection for this option.

Non-Summit device Identifies the destination system as one on which K2 Summit/SAN services are not running. When selected, an Enter working bin field opens. This is the bin on the destination system to which the asset is sent. The bin name must be entered manually, as only systems running K2 Summit/SAN services can populate a list of available bins/directories.
Note: When this option is selected, the settings applied for the destination system name and working bin name must be valid and accessible on the network. The GV STRATUS system does not attempt to validate the settings and does not provide any messages if not valid when applied.
Select a working bin The bin on the selected K2 system to which the asset is sent. This list of available bins does not appear if Non-Summit device is selected.