Other Topic Library Versions

Configure iNews for Monitor On

The iNews system must be installed and operational.
  1. In the SYSTEM.MOS-MAP configuration, verify or configure according to the following example:
    TABLE-START DeviceTable
    CAMIO        moscg        A B C D
    stratusuk    vidmos
    TABLE-END
  2. In the SYSTEM.MAP configuration, verify that the MOS reference for video is on the first line according to the following example:
    rundowns.bulletins.test      rundowns.bulletins.test                 -                      
            		  monitor              1505
    	 mossvr           uk004                -          mct-cg   
    	 mos              vidmos              UPDATE        -
     	mos               moscg               -         storytext

    If the MOS reference for video is on the second line, the status is not reported.

  3. In the story form and the rundown queue form, add the following fields:
    Option Description
    Current field: Label MOS TITLE
    Current field: Label size mos-title
    Current field: Type 10
    Current field: Edit size 15
    Attributes: Read-Only Selected
    Attributes: Affects Ready Selected
    Attributes: Write Group !<none>
    Type: Editbox Selected
    Option Description
    Current field: Label MOS DUR
    Current field: Label size mos-duration
    Current field: Type 7
    Current field: Edit size 7
    Attributes: Read-Only Cleared
    Attributes: Affects Ready Selected
    Attributes: Write Group !<none>
    Type: Duration Control Selected
    Option Description
    Current field: Label MOS
    Current field: Label size mos-active
    Current field: Type 5
    Current field: Edit size 16
    Attributes: Read-Only Selected
    Attributes: Affects Ready Cleared
    Attributes: Write Group !<none>
    Type: Editbox Selected
    Option Description
    Current field: Label Event Status
    Current field: Label size event-status
    Current field: Type 10
    Current field: Edit size 9
    Attributes: Read-Only Cleared
    Attributes: Affects Ready Cleared
    Attributes: Write Group !<none>
    Type: Editbox Selected
  4. Copy the MOS objects into the rundown.
Status is displayed.

Copyright © 2018 Grass Valley Canada. All rights reserved. GV STRATUS 6.5 gvtp_20181001_01:18:31