Render Engine Settings
These settings are required on GV STRATUS systems.
To locate these settings, in GV STRATUS Control Panel click Core | Engines | Render Engine | Modify
Setting or button | Description |
---|---|
Summit Access Protocols | The Summit Access protocol is a common configuration
that must be the same for all GV Render Engine servers. Different K2 Summit
servers might be accessed via different protocols. Select the Summit Access
Protocol for your Render Engine server from the following:
Note: When a Render Engine accesses high-res media on a standalone K2 Summit or
a K2 Central server, FTP is ALWAYS the preferred method. It is
recommended to use iSCSI or LAN Connect with K2 SAN configurations, and SMB
with GV AMS Pro - Advanced Media Storage configurations.
|
Maximum Concurrent Transcode Jobs | Setting to specify the maximum number of concurrent transcode jobs allowed on the Render Engine server. |
Maximum Concurrent Proxy Creation Jobs | Setting to specify the maximum number of concurrent proxy encoder jobs allowed on the Render Engine server. |
Maximum Concurrent Conform Jobs | Setting to specify the maximum number of concurrent conform jobs allowed on the Render Engine server. |
Maximum Concurrent EDIUS Project Jobs | Setting to specify the maximum number of concurrent EDIUS project jobs allowed on the Render Engine server. |
Maximum Total Concurrent Jobs | Setting to specify the maximum number of total concurrent jobs allowed on the
Render Engine server. Note: The maximum number for the setting is up to 4 concurrent jobs in
total.
|
Note: The total number of maximum concurrent jobs is limited by the number of available
simultaneous connections with K2 Summits. If set to zero, the Render Engine does not
process jobs of that type. Use these settings to balance resource load on the system
hosting the engine.