To ensure correct status reporting between GV STRATUS Rundown and iNEWS server, you need to edit the status
translation table in the iNEWS configuration file.
-
The status translation table within the mosconfig.xml file should
appear as below:
<statusTranslations>
<statusUnavailable>NOT READY</statusUnavailable>
<statusCueing>CUEING</statusCueing>
<statusAvailable>READY</statusAvailable>
<statusCued>STAND BY</statusCued>
<statusPlaying>PLAY</statusPlaying>
<statusPaused>STOPPED</statusPaused>
<statusStopped>END</statusStopped>
<statusUnknown>DISCONNECTED</statusUnknown>
</statusTranslations>
-
On the iNEWS server,
your MCS dictionary (located at /site/dict/mcs) would typically contain these
lines:
A_EVERR /5ERROR
A_CAFRZ /END
A_CATREL /2STANDBY
A_CATHRD /THREAD
A_CACUING /2CUEING
A_CACUED /2CUED
A_CANOTAPE /4NOT READY
A_CABIN /READY
A_CAPLAY /3PLAY
A_CAPAUSE /3STOPPED
A_CAREW /REWIND
A_CAEJECT /EJECT
A_CAINCMPLT /TRANSFER
Note: Since the statuses
that appear in this dictionary can be customized, the values shown in the right
column of your MCS dictionary may vary slightly from the ones shown here.
To ensure correct configuration with iNEWS, a sample of the mosconfig.xml
file is provided in the appendix section.