Do this for all systems with Render Engines. Whether you received your system
pre-configured from Grass Valley or you configured your system on site, you should test
the proxy encoding from one GV STRATUS client
PC before proceeding.
-
In the
GV STRATUS
application, identify a high-resolution asset and do the following:
-
In the Navigator, select the
high-resolution asset on the K2 Summit system.
The asset
appears in the Asset List.
-
Display the Has Proxy column in the Asset
List.
-
Verify that the asset has a proxy association.
-
Make sure the asset has not recently been used by any GV STRATUS tool
or panel.
An asset can retain an association with the tool or panel that
recently used it and prevent proxy from being regenerated.
-
In the Asset List, right-click the
high-resolution asset and select
Regenerate
Proxy.
-
Verify the following behavior:
-
In the Associations tab of the
Inspector, the proxy association is momentarily not visible.
This occurs as the
GV STRATUS
system deletes the proxy asset.
-
In the Associations tab of the Inspector, the
proxy association shows as recording.
This occurs due to the GV
Render Engine is in the process of
regenerating the proxy asset.
-
In the Associations tab of the
Inspector, the proxy association is visible again.
This occurs as a result of the GV Render Engine has finished regenerating the proxy asset.