Open Storage Utility and in the tree view expand all nodes so that
all disks are displayed.
On the K2 Summit system, remove the front bezel assembly.
Note: Replace the bezel assembly within one minute to maintain system
cooling.
The tables below illustrates the position of drives as numbered in
the
K2 Summit system chassis. Compare the drive number
positions and the disk numbering displayed in Storage Utility to identify drive
locations.
K2 Summit 3G+ Production Client
Position yourself so you can see the RAID drive LEDs.
Identify the disks in a LUN or identify a single disk, as follows:
In the Storage Utility tree view, right-click a LUN or
right-click a single disk, then select
Identify LUN or
Identify Disk
in the context menu.
A message box opens with a message that informs you that a
disk or disks are blinking.
View disks.
The LEDs display an amber color flashing several times a
second. This flashing pattern can stop automatically after a specific time
interval, such as ten seconds.