Service LED
The following table explains the status conditions indicated by the
different Service LED behaviors. If two or more status conditions occur
simultaneously, the LED displays the behavior for the highest priority
condition.
LED behavior | Status Condition | Priority |
---|---|---|
Flashing pattern alternating Yellow/Green/Red/Off twice a second | Identify — The K2 Summit system is being directed to identify itself by a monitoring application. | 1 |
Solid Red | Global failure — The K2 Summit system software has detected a critical error or failure that impacts record/play operations. | 2 |
Solid Yellow | Warning — The K2 Summit system software has detected a problem that requires attention but does not immediately impact record/play operations. For example, a fan or power supply has failed but its redundant partner is maintaining functionality. | 3 |
Flashing Yellow pattern three times a second. | Drive failure — An internal RAID drive has failed. If RAID 1, the failure does not immediately impact record/play operations. The redundant partner RAID drive is maintaining functionality. | 4 |
Flashing pattern alternating Yellow/Green once a second. | Drive rebuild — If RAID 1, an internal RAID drive is rebuilding. | 5 |
Off | Normal — The K2 Summit system is healthy and operating normally. | 5 |