Environmental specifications

The K2 Summit 3G system specification is shown in the following table:
Characteristic Specification
Ambient Temperature Non-Operating -40° to +60° C
Ambient Temperature Operating 10° to +40° C
Relative Humidity Operating 20% to 80% from 10° to +40° C

Non-Operating 10% to 85% from -30° to +55° C

Do not operate with visible moisture on the circuit boards

Operating Altitude To 10,000 feet

IEC 950 compliant to 2000 meters

Storage Altitude To 40,000 feet
Non-Operating Mechanical Shock 30G 11 ms trapezoid
Random Vibration Operational 0.27 GRMS (5-500Hz)
Random Vibration Non-Operational 2.38 GRMS overall

.019 g2/Hz (5-100Hz)

.009 g2/Hz (200-350Hz)

.0065 g2/Hz (500 Hz)

Equipment Type Information Technology
Equipment Class Class 1
Installation Category Category II Local level mains, appliances, portable equipment, etc.
Pollution Degree Level 2 operating environment, indoor use only.
The first generation K2 Summit/Solo system specification is shown in the following table:
Characteristic Specification
Ambient Temperature Non-Operating -40° to +60° C
Ambient Temperature Operating 10° to +40° C
Relative Humidity Operating 20% to 80% from 10° to +40° C

Non-Operating 10% to 80% from -30° to +60° C

Do not operate with visible moisture on the circuit boards

Operating Altitude To 10,000 feet

IEC 950 compliant to 2000 meters

Storage Altitude To 40,000 feet
Non-Operating Mechanical Shock 30G 11 ms trapezoid
Random Vibration Operational 0.27 GRMS (5-500Hz)
Random Vibration Non-Operational 2.38 GRMS overall

.0175 g2/Hz (5-100Hz)

.009375 g2/Hz (200-350Hz)

.00657 g2/Hz (500 Hz)

Equipment Type Information Technology
Equipment Class Class 1
Installation Category Category II Local level mains, appliances, portable equipment, etc.
Pollution Degree Level 2 operating environment, indoor use only.

Specifications vary for transmission products.


Copyright © 2014 Grass Valley. All rights reserved. K2 Summit 9.3 gvtp_20140914_19:56:32