Forcing a disk to rebuild

With RAID 0 there is no RAID redundancy, so disks do not rebuild. With other RAID types, such as RAID 1, if media access (record/play) is underway, when you insert a media disk it automatically begins to rebuild. If there is no media access underway, to start the rebuild process either begin a media operation or use the following procedure:

  1. In the tree view, identify the faulty disk . If the disk is not currently in the fault state, the Rebuild option is not available.
  2. In the tree view, right-click the faulty disk and select Rebuild.
  3. When the message “Succeeded to start rebuild…” appears, click OK. If internal storage, the Service LED on the K2 system displays a flashing pattern alternating yellow/green once a second.

Copyright © 2014 Grass Valley. All rights reserved. K2 Summit 9.3 gvtp_20140914_19:56:32