Other Topic Library Versions

Compatible K2 RAID components

This compatibility specification applies to K2 10Gv2 RAID (M100), K2 10G RAID (D4), and K2 Lx0 RAID (D3) on a K2 SAN, both basic and redundant. RAID firmware is compatible with this release of K2 software as follows:

Find firmware on the K2 client (for direct-connect storage) or the K2 Media Server (for shared storage) at C:\profile\microcode\External Storage\K2_L10-L40 Condor\Controller and at C:\profile\microcode\External Storage\K2_L10-L40-M100\Controller.

Component Version File Name Comments
Level 10/20 controller firmware for primary chassis with 15K SAS drives or SATA drives 07VS D1_07VS.BIN This version is still compatible for 300 and 450 GB drives
07VV D1_07VV.BIN This version is still compatible for 300 and 450 GB drives
07VW D1_07VW.BIN This version required for 600 GB drives, recommended for 300 and 450 GB drives. Requires version 050B for expansion chassis.
Level 10/20 controller firmware for expansion chassis with 15K SAS drives or SATA drives 030F ENCL_030F.BIN This version is still compatible for 300 and 450 GB drives with 07VS or 07VV controller firmware.
050B ENCL_050B.BIN This version is compatible for 300 and 450 GB with 07VS, 07VV, or 07VW controller firmware. Required for 600 GB drives with 07VW controller firmware.
Level 10/20 controller firmware for primary chassis with 7.2K SAS drives 07VV D1_07VV.BIN 7.2K SAS drives are used in K2 Production Storage and K2 Nearline Storage.
Level 10/20 controller firmware for expansion chassis with 7.2K SAS drives 050B ENCL_050B.BIN
Level 30/35 controller firmware for primary chassis with 15K SAS drives or SATA drives 07VS D3_07VS.BIN This version is still compatible for 300 and 450 GB drives
07VV D3_07VV.BIN This version is still compatible for 300 and 450 GB drives
07VW D3_07VW.BIN This version required for 600 GB drives, recommended for 300 and 450 GB drives. Requires 050B for expansion chassis.
Level 30/35 controller firmware for expansion chassis with 15K SAS drives or SATA drives 030F ENCL_030F.BIN This version is still compatible for 300 and 450 GB drives with 07VS or 07VV controller firmware.
050B ENCL_050B.BIN This version is compatible for 300 and 450 GB with 07VS, 07VV, or 07VW controller firmware. Required for 600 GB drives with 07VW controller firmware.
Level 30/35 controller firmware for primary chassis with 7.2K SAS drives 07VV D3_07VV.BIN 7.2K SAS drives are used in K2 Production Storage and K2 Nearline Storage.
Level 30/35 controller firmware for expansion chassis with 7.2K SAS drives 050B ENCL_050B.BIN
10G controller firmware for primary chassis with either 7.2K or 15K drives 01VP D4_ 01VP.BIN
10G controller firmware for primary chassis with either 7.2K or 15K drives 01VR D4_ 01VR.BIN Upgrade to this version is recommended but not required.
10G controller firmware for expansion chassis with either 7.2K or 15K drives 020F ENCL_020F.BIN
10Gv2 controller firmware for expansion chassis with either 7.2K or 10K drives U22R 91SC022R_101.bin M91_SC082R_101_U22R_101.inf

Copyright © 2015 Grass Valley USA, LLC. All rights reserved. K2 Summit 9.4 gvtp_20150218_00:14:46