Other Topic Library Versions

K2 Summit 3G Rack specifications

Use the following specifications to determine load, spacing, power, and other factors when planning system racks. These specifications apply to K2 Summit 3G chassis.

Table 1. Mechanical specifications
Characteristic Specification
Cabinet Type Rack-mount
Rack units 2
External Dimensions 447 x 617 x 89 mm
Weight 25.0 kg maximum
Table 2. Power specifications
Characteristic Specification
Power conditions Dual, redundant
Mains Input Voltage 90 to 260V auto-range, 47-63Hz
Maximum power consumption (when operating in a 25° C environment) 450W typical (standalone)

390W typical (SAN client)

Maximum AC current 8A @ 115VAC, 4A @ 230VAC