Powering on K2 G10v2 RAID

This topic applies to K2 G10v2 (M100) RAID.
  1. Verify power and cabling.
  2. Tap the power button on the controller, as shown.
    Note: Do not press and hold down the power button.
    If the RAID chassis has two controllers, you can tap the power button on either controller. You do not need to tap both power buttons. Tapping the power button on a controller also powers on any connected Expansion chassis. There are no power buttons on Expansion chassis.
  3. Wait while the primary RAID chassis performs self-test and initialization. This takes 6-8 minutes. While this is taking place, the Ready LED is illuminated with a steady on light.
  4. Watch for the Ready LED to begin blinking at one second intervals. The LED might turn off and back on two times before starting the one second blink pattern. When the Ready LED is blinking at one second intervals, the self-test and initialization is complete and the chassis is ready for use.