Other Topic Library Versions

Replacing a RAID 0 drive

If configured as RAID 0, when one drive fails, all media is lost. To replace a RAID 0 drive, do the following:

  1. Unbind the LUN that has the failed drive.
  2. Remove the failed drive from the K2 Summit system chassis.
  3. Insert the replacement drive in the K2 Summit system chassis.
  4. Restart the K2 Summit system.
  5. Using Storage Utility on the K2 Summit system, bind disks as RAID 0.
  6. Restart the K2 Summit system.
  7. Using Storage Utility on the K2 Summit system, make a new file system.

    Always use the Storage Utility to physically identify the failed drive. To identify a drive, in Storage Utility right-click the drive and select Identify. This causes the disk lights to flash.

    Refer to related topics in the "Configuring the K2 System" section of this Topic Library for Storage Utility procedures.

    To remove and insert a drive, refer to the mechanical procedure for disk module removal.