Replacing a Middle System Fan

Fans in the middle system are hot swappable. Each fan can be replaced while the system is running if the other fans are still operating. WARNING: Do not operate the K2 Central-Tx Server without the cover in place except for short periods of time for repairs. The chassis cover must be in place for proper airflow and to prevent overheating.

  1. Remove the chassis cover while the system is still running
  2. Identify which fan has failed. Depress the tab on the side of the fan to unlock it. Pull the fan straight up to remove it.
  3. Position the new fan into the same position as the one that was removed. Press it down until the side tab clicks and the fan locks in place.
  4. Replace the chassis cover.