Other Topic Library Versions

FT Server Rack specifications

Use the following specifications to determine load, spacing, power, and other factors when planning system racks.

Table 1. Mechanical specifications
Characteristic Type I and Type II Specification
Cabinet Type Rack-mount
Rack units 4
External Dimensions 483 (w) x 178 (h) x 736 (d) mm, 19.0 in. (w) x 7.0 in. (h) x 28.9 in. (d)
Rack clearance 40 cm or more on top, 1 m or more on the front and rear, 60 cm or more on the right and left.
Weight Maximum 51.5kg , 113.3 lbs
Table 2. Power specifications
Power Supply Type I Specifications Type II Specifications
Type AC 100V-240V +/- 10%, 50/60Hz +/- 3Hz AC 100V-240V +/- 10%, 50/60Hz +/- 3Hz
Power Consumption 1400VA, 1390W 1300VA, 1290W

Copyright © 2019 Grass Valley Canada. All rights reserved. K2 Summit 9.8 gvtp_20190519_03:02:01