Verifying the GV I/O configuration
- Valid signal feed must be connected to the inputs of GV I/O server.
- The required licenses have been added to the GV I/O Live Ingest and Playout Server. For more info, refer to SabreTooth GV I/O license process.
- Embedded Security Manager on the GV I/O device had been set to Enabled mode.
- For the GV I/O client of GV AMS Pro - Advanced Media Storage system, the V: drive of the GV I/O had been mapped to the UNC path of the system's hi-res media storage.
- For GV I/O Standalone devices, share the V: drive with “Everyone”.
- For GV I/O devices with SD and HD workflows, the configuration can be done via GV STRATUS Control Panel or the GV I/O web configuration utility.
- For GV I/O devices that support UHD, HDR, and NMOS workflows, configuration must only be done via the GV I/O web configuration utility. For more info, refer to Configuring the GV I/O Live Ingest and Playout Server.
Within the GV STRATUS system, do the following to verify the GV I/O Live Ingest and Playout Server is configured properly. Grass Valley recommends the GV STRATUS Control Panel is only configured on the Core Server: